1) How can fenestration products meet the U-factor requirements? (R402.3.1)
2) Which fenestration products can use area-weighted averaging to satisfy the SHGC requirements? (R402.3.2)
3) What minimum ratio of higher to lower labeled SHGC is required for dynamic glazing to satisfy the SHGC requirements? (R402.3.2)
4) How much glazed fenestration per dwelling unit is exempt from the U-factor and SHGC requirements? (R402.3.3)
5) What opaque door assembly is exempt from the U-factor requirement? (R402.3.4)
6) What is the maximum U-factor allowed for fenestration in sunrooms and heated garages with thermal isolation in Climate Zones 2 through 8? (R402.3.5)
7) What is the maximum skylight U-factor allowed for sunrooms and heated garages with thermal isolation in Climate Zones 2 through 8? (R402.3.5)
8) How must new fenestration separating a sunroom or heated garage with thermal isolation from conditioned space comply? (R402.3.5)
9) According to Section R402.1.2, fenestration shall have a U-factor and glazed fenestration SHGC equal to or less than that specified where? (R402.1.2)
10) What does the IECC require for all compliance approaches to achieve additional energy efficiency? (R401.2.5)
11) What is the purpose of an eave baffle as described in Section R402.2.3? (R402.2.3)
12) What is the alternative when the total building thermal envelope UA is less than or equal to the total UA resulting from U-factors in Table R402.1.2? (R402.1.5)
13) In what type of climate zone is skylight SHGC permitted to exceed 0.30? (Table R402.1.3 Note b)
14) What is the minimum wall cavity insulation R-value requirement for Climate Zone 6 according to Table R402.1.3? (Table R402.1.3)
15) For mass walls in Climate Zone 3, what is the maximum U-factor allowed when more than half the insulation is on the interior? (Table R402.1.2 Note b)
16) In Warm Humid locations as defined by Figure R301.1 and Table R301.1, what is the maximum basement wall U-factor allowed? (Table R402.1.2 Note c)
17) According to Table R402.1.3, what is the minimum floor R-value required in Climate Zone 3? (Table R402.1.3)
18) What is the maximum fenestration U-factor in Climate Zone 0 according to Table R402.1.3? (Table R402.1.3)
19) How should the R-values of cavity insulation be determined when installed in multiple layers? (R402.1.4)
20) What value should be used for blown-in insulation according to Section R402.1.4? (R402.1.4)
21) Can cavity insulation R-values be used to determine compliance with continuous insulation R-value requirements? (R402.1.4)
22) What should computed R-values not include according to Section R402.1.4? (R402.1.4)
23) What is required when floor framing cavity insulation extends from the bottom to the top of all perimeter floor framing members? (R402.2.7)
24) How must joints of the vapor retarder in unvented crawl space foundations be treated? (R402.2.10.1)
25) What must the UA calculation be performed with according to Section R402.1.5? (R402.1.5)
26) What must the UA calculation include according to Section R402.1.5? (R402.1.5)
27) According to Table R402.1.3, what is the required slab R-value and depth for Climate Zone 4 (except Marine)? (Table R402.1.3)
28) For what climate zones is there no SHGC requirement according to Table R402.1.2? (Table R402.1.2)
29) What is the exception to the requirement that dynamic glazing be automatically controlled to modulate solar gain? (R402.3.2)
30) What is the maximum ceiling U-factor for Climate Zone 7 according to Table R402.1.2? (Table R402.1.2)
31) What is the minimum basement wall R-value for Climate Zone 5 according to Table R402.1.3? (Table R402.1.3)
32) What does "13&5" mean in the context of Table R402.1.3? (Table R402.1.3 Note g)
33) What is the maximum fenestration U-factor allowed in Marine Climate Zone 4 for vertical fenestration products installed in buildings located above 4,000 feet in elevation? (Table R402.1.2 Note f)
34) According to Table R402.1.3, what additional insulation is required under heated slabs? (Table R402.1.3 Note d)
35) Which chapter applies to residential buildings according to the IECC? (R401.1)
36) What documentation is required regarding the Energy Rating Index score for buildings where an ERI score is determined? (R401.3)
37) What information must be included on the permanent certificate regarding air leakage testing? (R401.3)
38) Which compliance option requires compliance with Section R407? (R401.2.4)
39) What must be installed according to Section R408.2 for buildings complying with the Prescriptive Compliance Option? (R401.2.5)
40) When using the Total Building Performance Option and choosing to install one of the additional efficiency package options, how should such measures be treated in the proposed design? (R401.2.5)
41) According to the IECC, the building thermal envelope shall be constructed to limit air leakage in accordance with which sections? (R402.4)
42) What requirement applies to sealing methods between dissimilar materials in the building thermal envelope? (R402.4.1)
43) According to Table R402.4.1.1, what is required for air sealing at rim joists? (Table R402.4.1.1)
44) Per Table R402.4.1.1, what is required for insulation installation at rim joists? (Table R402.4.1.1)
45) Which of the following is NOT required to be sealed according to Table R402.4.1.1? (Table R402.4.1.1)
46) For the building thermal envelope air leakage test, what is the maximum allowable air leakage rate in any climate zone under any compliance path? (R402.4.1.2)
47) Which testing standard is NOT mentioned as acceptable for building air leakage testing? (R402.4.1.2)
48) During a building air leakage test, what should be done with interior doors? (R402.4.1.2)
49) During a building air leakage test, what should be done with heating and cooling systems? (R402.4.1.2)
50) What is the maximum air leakage rate allowed when testing individual dwelling units in attached single and multiple-family buildings? (R402.4.1.2)
51) In Climate Zones 3 through 8, what is the maximum air leakage rate when complying with Section R401.2.1? (R402.4.1.3)
52) What requirements apply to new wood-burning fireplaces? (R402.4.2)
53) What is the maximum air infiltration rate allowed for windows and skylights? (R402.4.3)
54) What is the maximum air infiltration rate allowed for swinging doors? (R402.4.3)
55) In Climate Zones 3 through 8, rooms containing fuel-burning appliances must meet what insulation requirement? (R402.4.4)
56) What minimum R-value is required for combustion air ducts passing through conditioned space? (R402.4.4)
57) Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage and must have what rating? (R402.4.5)
58) What is the maximum allowed air leakage rate for recessed luminaires when tested at a pressure differential of 1.57 psf? (R402.4.5)
59) Electrical and communication outlet boxes installed in the building thermal envelope shall be tested in accordance with which standard? (R402.4.6)
60) What is the maximum allowed air leakage rate for electrical and communication outlet boxes at a pressure differential of 1.57 psf? (R402.4.6)
61) In Climate Zones 4 and 5, what is the maximum area-weighted average U-factor permitted for vertical fenestration when using tradeoffs? (R402.5)
62) In Climate Zones 4 through 8, what is the maximum area-weighted average U-factor permitted for skylights when using tradeoffs? (R402.5)
63) What requirement applies to thermostats controlling primary heating or cooling systems? (R403.1.1)
64) What is the maximum heating temperature setpoint required for manufacturer programmed thermostats? (R403.1.1)
65) What is the minimum cooling temperature setpoint required for manufacturer programmed thermostats? (R403.1.1)
66) Heat pumps with supplementary electric-resistance heat shall have controls that prevent supplemental heat operation when? (R403.1.2)
67) What requirement applies to hot water boiler temperature controls? (R403.2)
68) What R-value is required for supply and return ducts 3 inches and larger in diameter located outside conditioned space? (R403.3.1)
69) What R-value is required for supply and return ducts smaller than 3 inches in diameter located outside conditioned space? (R403.3.1)
70) For ductwork to be considered inside a conditioned space, which is NOT a compliance option? (R403.3.2)
71) For ducts in floor cavities over unconditioned space to be considered in conditioned space, what minimum R-value insulation must be installed in the cavity? (R403.3.2)
72) For ducts located within exterior walls of the building thermal envelope, what minimum insulation must be installed between the duct and outside sheathing? (R403.3.2)
73) What minimum R-value is required for supply and return ducts that are partially or completely buried in ceiling insulation? (R403.3.3)
74) In Climate Zones 0A, 1A, 2A, and 3A, supply ducts completely buried within ceiling insulation must have a minimum R-value of? (R403.3.3)
75) When using the Total Building Performance Compliance Option, what effective R-value can be claimed for deeply buried ducts surrounded with blown-in attic insulation of R-30 or greater? (R403.3.3.1)