1) Where a public sewer is not available, the sanitary drainage piping system shall be connected to a (P2,602.1)?
2) A plumbing pipe going through a foundation wall shall be sleeved where the sleeve shall be greater than the pipe size by what multiple (P2,603.4)?
3) When trenching to install plumbing related piping next to a foundation, the bearing plane must be avoided. The bearing plane is defined as a line that extends downward from the foundation footing at what angle (P2,604.4)?
4) Unless specific intermittent supports are installed, piping underground for plumbing uses shall be laid on what for its entire length (P2,605.1)?
5) A toilet shall not be set closer than how far from its center to any side wall (P2,705.1(5))?
6) What is the minimum clearance in front of a toilet to a wall (P2,705.1(5))?
7) What is the minimum shower compartment interior cross-sectional area and minimum dimension (P2,708.1)?
8) Fold-down seats shall be permitted in the shower provided that the required minimum area is maintained when the seat is (P2,708.1 Exception 1)?
9) Individual shower valves shall (P2,708.4)?
10) The minimum size of a maintenance access opening to whirlpool bathtub circulation pump shall be (P2,720.1)?
11) The minimum size of a drain from a macerating toilet system is (P2,723.2)?
12) Non-potable water outlets such as hose connections shall be identified with (P2,901.2.1)?
13) What is the minimum air gap for backflow protection where required (P2,902.3.1, Table 2,902.3.1)?
14) What is the maximum water consumption flow rate for a handheld shower spray head (Table 2,903.2)?
15) What is the maximum static water pressure in a plumbing system (P2,903.3.2)?
16) What is the minimum diameter of a water service line (P2,903.7)?
17) What is the water supply fixture unit value for a kitchen sink (Table P2,903.6)?
18) Residential sprinklers shall have a temperature rating range in degrees Fahrenheit of (P2,904.2.1)?
19) Intermediate temperature sprinklers shall have a rating not less than what (P2,904.2.2)?
20) Intermediate temperature sprinklers systems are required to be used if within what distance range from the front of a recessed fireplace (Table P2,904.2.2)?
21) To avoid horizontal separation requirements between sewer and potable water lines, the water service pipe is required to be how much higher above the sewer line (P2,906.4.1)?
22) Unless there are provisions to protect from freezing conditions, drainage, waste and vent systems shall not be in (P3,001.2)?
23) Galvanized steel piping used for waste drains shall not be used underground and shall be kept not less than how far above ground (P3,002.1, Table P3,002.1(1))?
24) How many Drainage Fixture Units (DFU) are in a 2-bath multiple-bath group? (P3,004.1, Table P3,004.1)?
25) Sewers with drainage lines under 8 inches shall have cleanouts located at intervals not more than how many feet (P3,005.2.2, P3,005.2.1)?
26) A four-inch horizontal drainage sewer pipe shall have a minimum slope of not less than have much vertical drop per foot of length (P3,005.3)?
27) How many DFUs on any horizontal fixture branch can be connected to a 3-inch pipe (Table P3,005.4.1)?
28) A 3-inch building drain has a slope of 1/8 inch per foot. How many fixture units can be connected to it (Table P3,005.4.2)?
29) On-site non-potable reuse water used for subsurface graywater soil absorption systems shall be (P3,009.6)?
30) Sewer vent terminals extending through the wall shall terminate not less than how far from a lot line (P3,103.1.4)?
31) A combination waste and vent system can serve all of the following except (P3,111.1)?
32) A single trap serving fixture outlets not more than 30 inches apart can serve up to how many fixtures for kitchen sinks (P3,201.6 Exception 2)?
33) The clear working area for energized panelboards shall be 36 inches in depth, 30 inches in width (or panel width if greater) and how high (E3,405.2, Figure 3,405.1)?
34) Overcurrent protection devices in panelboards shall not be placed in all of the following locations except (E3,405.5)?
35) Which of the following individual conductor insulation type is acceptable (E3,406.5)?
36) All circuit conductors between the service equipment and the final branch circuit overcurrent device is a (E3,501 definitions)?
37) The maximum number of disconnecting means for any service shall be grouped and not exceed how many (E3,601.7)?
38) The minimum ampacity serving a one-family residence is (E3,602.1)?
39) The minimum service load calculation is based upon how many Volt-Amps per square foot of floor area for lighting and general use receptacle outlets (Table E3,602.2)?
40) With no correction factors required, a single-phase dwelling service rating for 100 Amps requires what size of ungrounded copper conductor (E3,603.1.1, Table E3,603.1.1)?
41) A 2 AWG copper service conductor requires a grounding electrode conductor of what minimum copper gauge (E3,603.4, Table E3,603.4)?
42) An interior metal water pipe shall not be used as a conductor to interconnect grounding electrodes if it is located more than how far into the building from the point of entrance (E3,608.1.1.1)?
43) A metal underground water pipe that is direct contact with the earth for how far shall be considered as a grounding electrode (E3,608.1.1.1)?
44) What is the minimum diameter of a stainless-steel rod type grounding electrode that is 8 feet long (E3,608.1.4)?
45) Rod and pipe electrodes shall be at least 8 feet in soil. If they can’t be driven in directly or at an oblique angle not to exceed 45 degrees from vertical, they can be buried in a trench that is at least how deep (E3,608.1.4.1)?
46) A plate grounding electrode is required to expose minimum square feet of what area to exterior soil (E3,608.1.5)?
47) Which of the following materials are prohibited from being a grounding electrode (E3,608.5, E3,608.1.4)?
48) Bar aluminum grounding electrode conductors external to buildings shall not be terminated within how far from the earth (E3,610.2(3))?
49) Branch circuit conductors for typical water heaters and electrical space heating equipment shall be sized not less than what percent of the equipment load (E3,702.10)?
50) A minimum of how many 20 Amp branch circuits shall be provided to all receptacle outlets in a kitchen (E3,703.2)?
51) The demand factor shall be 100 percent for the first 3,000 VA of calculated feeder load and what percent in excess of 3,000 VA? (Table E3,704.2(1))?
52) The maximum overall demand for 2 typical electric ranges in a residence is (Table E3,704.2(2))?
53) 75-degree Celsius rated Type THHW 1 AWG copper is rated for how many amps (Table E3,705.1)?
54) The Underground Service Cable Allowable Wiring Method has a designated abbreviation of (Table E3,801.2)?
55) What is the minimum depth of cover for nonmetallic raceways directly buried without concrete encasement under a driveway that is used to serve a one-family dwelling (Table E3,803.1)?
56) Underground service conductors that are not encased in concrete and are buried 18 inches or more below grade shall have their location identified by a warning ribbon that is placed in the trench not less than how far above the underground installation (E3,803.2)?
57) Receptacles placed in a family room shall be installed so that no point measured horizontally along the floor line of any wall space is more than how far from a receptacle outlet (E3,901.2.1)?
58) Receptacles placed on kitchen walls shall be placed so that no point along the wall shall be more than how far from a receptacle outlet (E3,901.4.1)?
59) At least one receptacle outlet shall be installed in a bathroom such that it is located within how far from the outside edge of each lavatory basin (E3,901.6)?
60) An outdoor outlet shall be installed at the (E3,901.7)?
61) A 125 Volt receptacle outlet shall be installed for the servicing of equipment within how far from the HVAC system to be serviced (E3,901.12)?
62) Which of the following are not required to be GFCI receptacles (E3,902.1, .2, .3)?
63) Mud room receptacles located within how many feet of the top inside edge of a cleaning sink bowl shall have GFCI protection (E3,902.7)?
64) Which of the following receptacle outlet locations are not required to be arc-fault circuit interrupter protected (E3,902.20)?
65) Receptacles controlled by a listed wall mounted control device shall be considered equivalent to the required lighting outlet in all habitable rooms except a (E3,903.2 Exception 1)?
66) A wall mounted control switch at each floor level is required in stairwells with more than how many risers (E3,903.3)?
67) How many 12 AWG THHN conductors are allowed within ½ inch Rigid PVC Schedule 40 conduit (Table E3,904.6(10))?
68) Outlet boxes supporting ceiling fans, marked by the manufacturer as suitable for this purpose, shall not support a fan weighing more than (E3,905.8)?
69) Electrical panelboards in wet locations shall be mounted to provide an airspace of not less than what distance between the enclosure and the wall (E3,907.2)?
70) A flexible metal conduit used as an equipment grounding conductor is permitted to be no longer than (E3,908.9.1)?
71) What is the minimum size of an aluminum grounding conductor for an overcurrent device ahead of equipment rated at 200 Amps (Table E3,908.13)?
72) What is the minimum amperage rating for receptacle outlets (E4,002.1, Table E4,002.1.2)?
73) Cord connected luminaires are prohibited within 3 feet horizontally and how far vertically from the top of a bathtub rim (E4,003.11)?
74) A recessed luminaire that is not identified for contact with insulation shall have all recessed parts spaced at least how far from combustible material (E4,004.8)?
75) Thermal insulation shall not be installed above a recessed luminaire or within how far of the recessed luminaire’s enclosure unless the luminaire is identified for contact with insulation (E4,004.9)?
76) Is GFCI protection required for snow melting outdoor equipment receptacle outlets (E4,101.7)?
77) A permanently installed swimming pool is defined as being deeper than (E4,201 Definitions)?
78) All 15 Amp receptacle outlets shall be Class A GFCI protected within how far from the inside walls of the pool (E4,203.1.4)?
79) An indoor 15 Amp receptacle outlet is required to be GFCI protected if it is within how far from a hot tub (E4,203.1.6)?
80) Metallic components of a pool such as underwater lighting shells, circulating pump motors, metal liners, handrails, etc, shall be bonded together using copper wires not less than what size (E4,204.2)?
81) A pool without bonded parts in direct connection with the pool water shall have a bonded conducted surface that is a minimum of what area exposed to the pool water (E4,204.3)?
82) A power supply to a self-contained hot tub shall be (E4,208.1)?