1) Interior wall covering products shall not be installed until (R701.2)?
2) Gypsum plaster over metal lath shall have how many coats (R702.2.1)?
3) What is the minimum thickness of cement based plaster over masonry walls from the face of metal lath (Table R702.1(1))?
4) What is the minimum support spacing for 3/8 inch metal lath on walls or ceiling (R702.2.3)?
5) Screws for attaching ½ inch gypsum panels on ceiling with 24 inch center shall be screwed every 12 inches maximum with what type of screws (R702.3.5.1, Table R702.3.5 and footnote b)?
6) Screws that attached ½ inch gypsum panels are required to be at least how long (R702.3.5.1, 5/8 + 1/2)?
7) Water resistant gypsum in a shower or tub compartment shall not be installed over a vapor retarder of what class (R702.3.7)?
8) The maximum center to center spacing of nails used for fastening ½ inch gypsum board that is glued onto studs spaced on 16 inches shall be (Table R702.3.5)?
9) No. 15 asphalt felt water resistive barrier covering exterior wall shall be applied horizontally with the upper layer lapped over the lower layer by not less than what length (R703.2)?
10) Nominal material thickness, unless specified by the manufacturer’s instructions, for wall siding is based on a maximum stud spacing of (R703.3, Table R703.3(1))?
11) What is the nominal thickness of vinyl for insulated vinyl siding (Table R703.3(1))?
12) What is the minimum penetration thickness for ½ inch crown staples when installing vinyl siding into wood structural panels (R703.3(1) footnote h)?
13) 3/8 inch thick wood structural panel exterior siding shall not be applied directly to studs spaced more than what distance (R703.5.2)?
14) In stucco construction, lath shall be attached with fasteners spaced not more that what distance on center along framing members (R703.7.1)?
15) Anchored stone and masonry veneer shall not exceed what thickness (R703.8)?
16) What is the maximum height of masonry veneer over a concrete foundation in seismic design category C (Table R703.8(1) footnote a)?
17) What is the maximum height of masonry veneer above the noncombustible foundation in a seismic design category D1 area (Table R703.8(2) footnote c)?
18) What is the maximum allowable span for a steel 3X3X1/4 inch lintel that support masonry veneer with no storing above it (Table 703.8.3.1)?
19) The size of anchorage of stone and masonry veneer shall be at least what gauge of steel (R703.8.4.1)?
20) EIFS with or without drainage shall terminate not closer than how high above the finished ground level (R703.9.1, R703.9.2)?
21) Fasteners used for vinyl siding shall penetrate into sheathing a minimum of how far (R703.11.1.2)?
22) For roof-ceiling construction using wood framing, what is the minimum nominal ridge board thickness (R802.3)?
23) 2X8 rafters on 16 inch centers supporting a ground snow load of 30 PSF and a L/delta = 180 with a dead load of 20 PSF and the ceiling not attached with a rafter span of 13 feet – 4 inches requires what grade of hem-fir (Table 802.4.1(3))?
24) What is the maximum center to center spacing for Number 1 Douglas fir-larch 2X6 rafters with 11 feet-5 inches of span supporting 30 PSF ground snow load with L/delta of 240 and the ceiling attached to rafters with a dead load of 20 PSF (Table R802.4.1(4))?
25) Purlins installed to reduce the span of rafters are required to have braces separated not more than how far (R802.4.5, Figure 802.4.5)?
26) What is the maximum spacing for collar ties that support opposing rafters (R802.4.6, Figure 802.4.5)?
27) The ends of each rafter or ceiling joist shall have not less than how much bearing on wood (R802.6)?
28) When framing openings a roof, the header joist shall be doubled when the header joist span exceeds what length (R802.9)?
29) Wood structural panels used as roof sheathing shall have joints (R803.2.3, Table R602.3(1))?
30) Cold formed steel ceiling joists shall have bearing support of not less than what length (R804.3.1.1)?
31) What is the cold formed steel member designation for unbraced 16 inch centers for a span of 15 feet – 10 inches (Table R804.3.1.1(1))?
32) Normally, the minimum net free ventilating area for a roof shall be what ratio of the area of the vented space such as enclosed attics (R806.2)?
33) The minimum ratio for vented attic space is permitted to be 1/300th if a class 1 or 2 vapor retarder is installed on the warm-in-winter side of the ceiling and not less than 40 percent or more than 50 percent of the required ventilation area is provided by ventilators located in the (R806.2 Exceptions)?
34) Where eave vents are installed, not less than what space shall be provided between the insulation and the roof sheathing at the location of the vent (R806.3)?
35) Buildings with combustible ceiling or roof construction shall have attic access openings to the attic areas that have a vertical height of (R807.1)?
36) The rough framed opening for attic access shall be not less than what minimum dimensions (R807.1)?
37) Class A roof assemblies include all of the following except (R902.1 Exceptions)?
38) The minimum thickness of metal used as flashings at roof intersections shall be (R903.2.1)?
39) Overflow drains for flat roofs shall not discharge to the normal (R903.4.1)?
40) Asphalt shingles can be used only on roof slopes at or above what pitch (R905.2.2)?
41) Double underlayment is required when using asphalt shingles for roof slopes between 2:12 and (R905.2.2, Table R905.1.1(2))?
42) Fasteners for asphalt shingles shall penetrate into the roof sheathing either through or at least how deep (R905.2.5)?
43) How many fasteners are required for each individual asphalt shingle (R905.2.6)?
44) Clay roof tile can be installed on roofs with a pitch at or above (R905.3.2)?
45) Metal roof shingles shall not be installed on roof slopes below what pitch (R905.4.2)?
46) Wood shingles shall not be installed on roof slopes below what pitch (R905.7.2)?
47) Wood shingles shall be laid with a side lap of not less than how far between joints (R905.7.5)?
48) Wood shingles require a minimum of how many fasteners each (R905.7.5)?
49) Valley metal flashing for wood shingles shall not be less than what thickness (R905.7.6)?
50) Sections of flashing shall have an end lap of not less than (R905.7.6)?
51) Wood shakes shall only be used on a roof slope of what minimum (R905.8.2)?
52) Spacing between wood shakes in the same course shall be between 3/8 inch to (R905.8.6)?
53) Wood shakes shall be interlaid with 18 inch wide strips of not less than felt of what size shingled between each course (R905.8.7)?
54) Reroofing over an existing roof is prohibited if the exiting roof has how many applications of any type of roof covering (R908.3.1.1(3))?
55) Reinstallation of existing roofing materials is permitted for which of the following (R908.5)?