2021 ICC Commercial Mechanical Inspector Quiz 3


Home Next Quiz

1) The use of Gypsum boards to form plenums shall be limited to systems where the air temperatures do not exceed? (602.2)

2) Gypsum board surfaces used for plenums shall be maintained at temperatures? (602.2)

3) Supply air plenums formed by gypsum boards for use in direct evaporative cooling shall (602.2)

4) A business occupancy can use a plenum made from wood floor joists only when? (602.2.1)

5) Plenums between wood floor joists are allowed in what kind of occupancy? (602.2.1 Exception 3)

6) Combustible electrical wires and cables and optical fiber cables exposed within a plenum shall be? (602.2.1.1)

7) Wiring in plenum space shall have a flame spread? (602.2.1.1)

8) Plastic fire sprinkler piping exposed within a plenum shall have a flame spread? (602.2.1.2)

9) Stud wall cavities used as supply air plenums shall? (602.3(1))

10) Stud wall cavities in the outside walls of the building envelope shall be allowed for air plenums when? (602.3(6))

11) Flexible air ducts shall be tested in accordance with?

12) Flexible air ducts shall be limited to what length? (603.6.1.1)

13) Flexible air connectors shall be limited to what length? (603.6.2.1)

14) The design temperature of air to be conveyed in flexible air ducts and connectors shall be less than? (603.6.3)

15) Underground metal ducts not having a protective coating shall be encased in not less than how much concrete? (603.8)

16) A 10 inch round steel duct in a single dwelling unit shall have a thickness not less than?

17) A 10 inch round aluminum duct in a single dwelling unit shall have a thickness not less than?

18) A 20 inch round steel duct in a single dwelling unit shall have a thickness not less than?

19) A 20 inch rectangular aluminum duct in a single dwelling unit shall have a thickness not less than?

20) Seams in ducts shall be securely fastened and sealed with welds, gaskets, mastics, tapes, etc, and shall be supported. Flexible and other factory made ducts shall be supported? (603.10, 603.9)

21) Ducts shall not be installed within how far from earth? (603.14)

22) Ducts installed in locations where they are exposed to mechanical damage by vehicles or from other causes shall be protected by? (603.15)

23) Ducts that operate at temperatures above 120 degrees F shall have suAicient thermal insulation to limit the exposed surface temperature to? (604.2)

24) Duct coverings and linings including adhesives shall have a flame spread index not more than? (604.3)

25) Duct coverings and linings including adhesives shall have a smoke-developed index not more than? (604.3)

26) Duct coverings and linings shall not flame, glow, smolder or smoke when tested in accordance with? (604.3)

27) Ducts that penetrate fire resistance rated assemblies shall have their duct covering? (604.6)

28) External duct insulation shall be identified at intervals not greater than 36 inches with all of the following except? (604.7)

29) A duct system with electric resistance or fuel burning heaters within the ducts shall have the linings on the ductwork removed not less than how far up and downstream of the heaters? (604.8)

30) Duct coverings shall not conceal service openings unless? (604.10)

31) Where ducts used for cooling are externally insulated, the insulation shall be covered with a vapor retarder. Insulation having a permeance of 0.05 perm or less shall? (604.11)

32) Heating and air-conditioning systems shall be provided with air filters except for? (605.1)

33) Liquid adhesive coatings used on filters shall have a flash point not lower than? (605.1)

34) Smoke detectors shall be installed in return air systems with a design capacity greater than? (606.2.1)

35) Upon activation of smoke detectors within ducting, the system shall cause the? (606.4)

36) Fire dampers shall comply with the requirements of? (607.3.1)

37) Smoke dampers shall comply with the requirements of? (607.3.1)

38) Ceiling radiation dampers shall comply with the requirements of? (607.3.1)

39) Fire dampers within 3-hour rated construction shall be rated for? (Table 607.3.2.1)

40) Where a smoke damper is installed within a duct, a smoke detector shall be installed inside the duct or outside the duct with sampling tubes protruding into the duct. The detector or tubes within the duct shall be within how far from the damper? (607.3.3.2(1))

41) Fire and smoke dampers shall be provided with an approved means of access that is? (607.4.1)

42) The access openings on ducts to service fire and smoke dampers shall have access doors that shall not reduce the fire resistance rating of the assembly and shall be? (607.4.1.1)

43) Access points on ducts to service fire and smoke dampers shall be permanently identified on the exterior by a lable having letters not less than what height? (607.4.2)

44) Listed fire dampers are required for ducts that penetrate fire partitions unless the duct shall not exceed what area? (607.5.3 Exception 3.1)

45) Smoke dampers are not required in corridor penetrations where the duct is constructed of steel not less than what thickness? (607.5.4 Exception 3)

46) Penetrations through fire rated shafts are permitted not to have fire dampers in parking garages provided such garages are separated from other building shafts by not less than what? (607.5.5 Exception 1.4)

47) Ceiling radiation dampers installed in heating systems designed to operate with fans on during a fire shall be labeled for use in? (607.6.2.1.1)

48) In floor assemblies composed of noncombustible materials, a shaft shall not be required where the duct connects not more than how many stories and the annular space around the penetrating duct is protected with an approved noncombustible material that resists the free passage of flame and a fire damper is installed at each floor line? (607.6.3(3))

49) Air distribution, ventilation and exhaust systems shall be provided with means to adjust the system to achieve the design airflow rates and shall be? (608.1)

50) Where combustion air openings are provided with volume, smoke or fire dampers, the dampers shall be? (701.2)