1) Which areas are not covered by the NEC? (90.2(A)(2), (4), (B)(5))
2) If something is capable of being reached quickly for operation or inspections without requiring tools or climbing over obstacles or using ladders is considered? (Article 100 Definitions)
3) Something that is acceptable to the AHJ? (Article 100 Definitions)
4) The maximum current that a conductor can carry continuously without exceeding its temperature rating? (Article 100 Definitions)
5) The connection between the grounded circuit conductor and the equipment grounding conductor at the service? (Article 100 Definitions)
6) The circuit conductors between the final overcurrent device protecting the circuit and the outlets is the? (Article 100 Definitions)
7) A branch circuit that supplies energy to one or more outlets to which appliance are to be connected and that has no permanently connected luminaires is a? (Article 100 Definitions)
8) A branch circuit that supplies two or more receptacles or outlets for lighting and appliances is a? (Article 100 Definitions)
9) A branch circuit that supplies only one utilization equipment is a? (Article 100 Definitions)
10) A branch circuit that consists of two or more ungrounded conductors that have a voltage between them is a? (Article 100 Definitions)
11) A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating is a? (Article 100 Definitions)
12) A breaker with a purposely introduced delay in tripping action to the circuit breaker, where the delay decreases as the magnitude of the current increases is a? (Article 100 Definitions)
13) A conductor encased within material of composition and thickness that is recognized as electrical insulation is a?
14) A load where the maximum current is expected to continue for three hours, or more is a? (Article 100 Definitions)
15) A light fixture is not a ______ but a receptacle is one? (Article 100 Definitions)
16) A feeder is all circuit conductors between the service equipment and the? (Article 100 Definitions)
17) Grounded means that it is? (Article 100 Definitions)
18) A device intended to de-energize a circuit within an established period when a fault exceeds the values established for a device is a? (Article 100 Definitions)
19) “In Sight From” means that something is visible and not more than how distant away? (Article 100 Definitions)
20) An electrical box under an outdoor canopy is in a? (Article 100 Definitions)
21) A load where the wave shape of the steady state current does not follow the wave shape of the applied load is? (Article 100 Definitions)
22) An arrangement electrically powered light sources that outlines certain features such as the shape of a building is a? (Article 100 Definitions)
23) A single contact device with no other contact device on the same yoke is a? (Article 100 Definitions)
24) A complete subassembly of parts and devices for field conversion of utilization equipment is a? (Article 100 Definitions)
25) An electrical source other than service that has no direct connection to circuit conductors of any other electrical source other than those established by grounding and bonding. An example is a generator. Solar Panels do not meet this definition oddly enough. What is this? (Article 100 Definitions)
26) The overhead conductors between the serving utility and the service point is a? (Article 100 Definitions)
27) A switch intended for use in general distribution and branch circuits is a? (Article 100 Definitions)
28) A switch rated in horsepower is a? (Article 100 Definitions)
29) A large single or multiple panels which switches overcurrent and are generally accessible from the rear and the front and are typically in cabinets is a? (Article 100 Definitions)
30) An electronically actuated fuse is a control module that provides all the following except?
31) What does not generate more than 1.5 V, 100 mA and 25 mW? (Article 100 Definitions)
32) Where the conductor material is not specified within the code, the sizes given in the code shall apply to? (110.5)
33) Conductor Sizes are expressed in AWG and? (110.6)
34) Where metallic plugs or plates are used with nonmetallic enclosure unused openings, they shall be recessed from the outer surface of the enclosure by how far? (110.12(A))
35) Wooden plugs driven into holes in masonry, concrete, plaster or similar materials shall? (110.13(A))
36) Connections by means of wire-binding screws permitted for what size? (110.14(A))
37) Terminals for more than one conductor shall be? (110.14(A))
38) The Ampacity of conductor selected shall not exceed the __________ of any termination, conductor or device? (110.14(C), (C)(1), (C)(1)(a)(2), Table 310.16)
39) Conductor with higher temp ratings: ampacity based upon 140 degrees F for termination. NM or NMC has insulated rated at 90° C, but ampacity rated at _________ is used in sizing for some applications? (110.14(C), (C)(1), (C)(1)(a)(2), Table 310.16)
40) Termination provisions for circuits rated over 100 A or larger than 1 AWG shall be used for conductors rated at? (110.14(C), (C)(1), (C)(1)(a)(2), Table 310.16)
41) Separately installed pressure connectors shall be used with conductors at the ampacities not exceeding the ampacity at the listed and identified temp rating of? (110.14(C), (C)(1), (C)(1)(a)(2), Table 310.16)
42) Where likely to require examination, adjustment, servicing or maintenance while energized, a switchboard shall be marked to warn qualified persons of? (110.16(A))
43) What is the working distance from electrical panels? (110.26(1) and (2), (3) including Exception No 2, Table 110.26(A)(1))
44) Large equipment requires one entrance to working area at least? (110.26 (C)(2)(b))
45) Where working space is twice that required by Table 110.26(A)(1) for large electrical equipment within a room, a? (110.26(C)(2)(b))
46) What is the minimum distance from door to equipment where the door and wall is not considered grounded? (Table 110.26(A)(1))
47) Personnel door where rated 800 A or more in working space shall? (110.26(C))
48) Personnel door where rated 800 A or more in working space shall be? (110.26(C))
49) Automatic illumination to control lighting in working space within electrical rooms is? (110.26(D))
50) Panel board in electrical room must have space of what distance above equipment OR TO structural ceiling dedicated to electrical installation? (110.26 (E)(1)(a))
51) Dropped or suspended ceiling within electrical workspaces that does not add strength to the building structure shall? (110.26(E)(1)(d))
52) Outdoor electrical installations shall have all the following, except? (110.26(E)(2)(2), (3))
53) Live parts under 50 V shall be? (110.27(A))
54) Guarding of live parts between 50 V to 300 V can be accomplished by? (110.27(A)(4)(a))
55) Outdoor installations of over 1,000 V equipment can be protected by a fence that is? (110.31)
56) What type of enclosure is not permitted for an environment that involvers blowing dust? (Table 110.28)
57) Outdoor enclosed equipment that is over 1,000 V that is accessible to unqualified persons can be guarded by? (110.31(D))
58) How heavy must a cover be to an outdoor underground box with electrical equipment over 1,000 V if it is not locked? (110.31(D))
59) Minimum clear work area shall not be less than how high in front of equipment that is 1,000 V or more? (110.32)
60) At least one entrance to electrical enclosures shall not be less than how wide to give access to the working space of electrical equipment? (110.33(A))
61) Where the depth of working space within electrical equipment enclosure spaces is twice what is required? (110.33(A)(1)(b)
62) What is the required minimum working space between unguarded live parts and
63) 6 AWG and small insulated grounded conductors can be identified having insulator with? (200.6(A))
64) 4 AWG and larger insulated grounded conductors can be identified having insulator with? (200.6(B))
65) Where grounded conductors of diAerent systems are installed in same raceway they can be identified with? (200.6 (D)(2))
66) Grounded conductors of multiconductor cables are permitted to be re-identified at their terminations by a? (200.6(E) Exception No 1)
67) For single pole, 3-way or 4-way switches in circuits of 50 V or more, re-identified conductors with white or gray insulation or three continuous WHITE OR GRAY stripes shall be used only for the? (200.7(C)(1))
68) In devices or utilization equipment with polarized connections, identification of terminals to which a grounded conductor is to be connected shall be? (200.9)
69) Receptacles shall have the terminal intended for connection to the grounded conductor identified as? (200.10(B)(1))
70) For devices with screw shells, the terminal for the grounded conductor shall be the one connected to the? (200.10(C))
71) Multi-Wire branch circuits shall be provided with means that will? (210.4(B))
72) Multiwire branch circuits shall supply only? (210.4(C))
73) In dwelling units, the voltage between conductors that supply the terminals for luminaires shall not exceed? (210.6(A))
74) Luminaires equipment with Mogal-base screw shall lamp-holders shall not exceed? (210.6(C)(4))
75) GFCI protection required in all the following except? (210.8(A), (1), (2), (3), (4), (B)(1))
76) Industrial occupancies where maintenance and supervision ensure that only qualified persons service the installation, auto-transformers shall be permitted to supply nominal 600-V loads without the connection to the? (210.9 Exception 2):
77) Small appliance branch circuits in kitchens within dwelling units require at least? (210.11(C)(1))
78) Dwelling unit laundry receptacles require how many 20 A circuits? (210.11(c)(2))
79) How many 20 A circuits are required for a bathroom in a dwelling unit? (210.11(c)(3))
80) How many 20 A circuits are required for a residential garage? (210.11(c)(4))
81) Outdoor receptacles can be supplied by the dedicated 20 Amp circuit in the? (210.11(c)(4) Exception)
82) All dwelling unit bedroom receptacles shall be? (210.12(A))
83) Residential branch circuits shall be rated in accordance with? (210.18)
84) What shall determine the ampere rating of a branch circuit? (210.18)
85) Branch circuits not over 600 V are designed not to drop more than? (210.19(A))
86) Where a branch circuit supplies continuous loads the minimum branch-circuit conductor size shall have an ampacity not less than the non-continuous load PLUS? (210.19(A)(1)(a))
87) Max individual item on a branch line shall not use more than what percent of the circuit rating? (210.19(A)(1)(a), [based upon 125 percent sizing])
88) Minimum branch circuit rating for domestic ranges of 8.75 kW or more shall be? (210.19(A)(1)(3))
89) Neutral conductor of a 3-wire branch circuit supplying an electric range shall be permitted to be smaller than the ungrounded conductors, but such conductor shall have an ampacity not less than 70 percent of the branch circuit rating AND? (210.19(A)(1)(3) Exception No 2)
90) Residential branch circuits shall not be smaller than? (210.19(A)(1)(4))
91) Lamp holders shall be of what type if connected to a branch circuit rated more than 20 A. (210.21(A))
92) A single receptacle on an individual 20 A branch circuit shall be rated for at least? (210.21(B)(1))
93) If a 20 A circuit has a 12 A dishwasher hooked into it, how big of a dedicated garbage disposal can be installed? (Table 210.21(B)(2))
94) Where connected to a branch circuit with two or more receptacles, what is the minimum receptacle rating? (Table 210.21(B)(3))
95) The rating of any one cord and plug connected utilization equipment not fastened in place SHALL NOT EXCEED what percent of the branch circuit amp rating? (210.23(A)(1))
96) The total rating (other than luminaires) for fastened in place utilization equipment SHALL NOT EXCEED what percent of the branch circuit ampere rating? (210.23(A)(2))
97) Cord and plug connected utilization equipment shall not exceed what percent of the branch circuit amperage rating in 30 Amp branch circuits? (210.23(A)(3))
98) In multi-dwelling unit, can fire alarm system circuit be supplied by an apartment manager’s dwelling unit given that this person performs electrical maintenance on apartment complex? (210.25(B))
99) Appliance receptacles for (laundry, etc) equipment in dwelling units shall be installed within what distance of intended location of the appliance? (210.50(C))
100) A switch-controlled receptacle in a bedroom does not qualify as a? (210.52(2))