1) After the final mechanical inspections, the Code Official shall have the right to require a mechanical system to be? (102.3)
2) For a change in occupancy, the system shall? (102.5)
3) Minor additions and repairs to existing systems shall? (102.4)
4) Where it is necessary to make an inspection to enforce the provisions of the code, the CO shall have the authority to enter the building at? (104.4)
5) Where there are practical difficulties involved in carrying out the provisions of the IMC, the code official shall have the authority to grant? (105.1)
6) If there are specific reasons that make the letter of the code impractical and the modification does not lessen health and life safety requirements, and the modification is recorded on file at the building department, it is acceptable for the CO to? (105.1)
7) An alternative material or design shall be approved by the CO if it is? (105.2)
8) In the absence of recognized and accepted test methods for materials used for a system, who shall approve the testing procedure used? (105.3.1)
9) Permits are required for which of the following? (106.2)
10) Exemption from the permit requirements of the IMC shall not authorize work that is? (106.2)
11) If work is not done within how long after a permit is issued, or if it is commenced than then stopped for how long before the permit is revoked? (106.4.3)
12) Two sets of construction docents shall be submitted, where one is kept at the building department for at least 180 days from the completion of the work, and the second set of plans is kept at? (107.1, 107.2)
13) Construction documents for buildings more than two stories in height shall indicate where penetrations will be made for mechanical systems and shall include the? (107.1)
14) The code official shall have the authority to?
15) The CO shall require construction documents to be prepared and designed by a registered design professional where? (107.1)
16) Who shall notify the CO the construction is ready for inspection (112.2)
17) Which of the following is not required to be inspected (112.2)
18) What is permitted to be backfilled prior to inspection?
19) Where excavated soil contains rocks, broken concrete, frozen chucks and other rubble that would damage or break the piping, what is required during inspection? (112.2)
20) A heating system can be replaced without a permit provided that a request for inspection for such heating equipment is submitted after the work within how long? (112.2)
21) Who is responsible for providing access and means for inspections of completed work at a job site? (112.2.2)
22) An appeal shall be based on a claim that the true intent of the code have been incorrectly interpreted, or the provisions of the code do not fully apply, or an
23) A stop work order shall be? (116.2)
24) The CO shall not be required to give a written notice prior to stopping work if? (116.3)
25) A panel that requires a ladder to access and screws to be removed from the panel is considered? (202)
26) Any combination of outdoor and transfer air intended to replace exhaust aire and exfiltration is considered to be? (202)
27) Air controlled for temperature, humidity and cleanliness is considered to be? (202)
28) A blower used for the purpose of distributing supply air to a room is a?
29) A high-heat appliance has a temperature? (202)
30) A low-heat appliance has an operating temperature rating of? (202)
31) A medium heat appliance has products of combustion at the point of entrance to the flue under normal operating conditions with a temperature? (202)
32) Low-pressure steam boilers operate at a pressure? (202)
33) Hot water boilers shall be limited to a pressure of? (202)
34) A brazed connection has filler metal having a melting point no lower than? (202)
35) BTU is defined as? (202)
36) A listed device installed in a ceiling membrane of a fire resistance rated ceiling to automatically limit the radiative heat transfer through an air opening is a? (202)
37) A field constructed chimney of metal is defined as a? (202)
38) Air necessary for complete combustion of a fuel including both theoretical air and excess are is? (202)
39) A heat exchanger designed to liquefy refrigerant vapor by removal of heat is a? (202)
40) An area within a building that is directly heated or cooled is considered a? (202)
41) A device that will retard or direct the flow of air in a duct is called a? (202)
42) All air for combustion is derived from the outdoor atmosphere and all flue gases are discharged to the outdoor atmosphere for what kind of appliances? (202)
43) A tube or conduit utilized for conveying air is a? (202)
44) A device used for reducing the sensible heat of air for cooling by the process of evaporation of water into an airstream is a? (202)
45) That part of the system in which liquid refrigerant is vaporized to produce refrigeration is? (202)
46) A cooking appliance utilizing open flame combustion of solid fuel at any time is a? (202, 507.2.2)
47) A listed a labeled fireplace and chimney system composed of factory made components and assembled in the filed in accordance with the manufacturer’s instructions is a? (202)
48) What is the lowest flammability classification for refrigerant? (202)
49) Flammable fumes or vapors are mixtures of gases in air at concentrations equal to or greater than the lower flammable limit and less than or equal to? (202)
50) The net floor area is the? (202)
51) A natural gas, manufactured gas, liquified petroleum gas or a mixture of these is a? (202)
52) A fusible plug is a device arranged and set at a predetermined temperature to lower? (202)
53) Piping buried or placed in a body of water for transporting heat transfer liquid to and from a heat pump is a? (202)
54) The parts of a refrigerating system subject to condenser pressure is the? (202)
55) A soldered joint is a gastight joint obtained by the joining of metal parts with alloys with a melting temperature between? (202)
56) A low-pressure hot-water-heating boiler furnishes hot water at a pressure and temperature not exceeding? (202)
57) The parts of a refrigerating system subject to evaporator pressure is the? (202)
58) Which of the following are considered medium-duty cooking appliances? (202)
59) How many bends does an Offset Vent make? (202)
60) An enclosed portion of the building structure that is designed to allow air movement as part of the air distribution system is a? (202)
61) A safety feature designed to relieve pressure automatically in excess of the device’s setting is a? (202)
62) Refrigerants reprocessed to the same specifications as for new refrigerants are called? (202)
63) What two refrigerant characteristics are used to define the refrigerant safety group classification? (202)
64) One horsepower is considered the same as how many BTU per hour? (202)
65) Air removed from an approved conditioned space or location and recirculated or exhausted is? (202)
66) A listed device installed in ducts designed to resist the passage of smoke is a? (202)
67) The air delivered to any space supplied by the air distribution system is? (202)
68) Which of the following is the highest refrigeration toxicity classification? (202)
69) Which of the following are permitted for a oil burning appliance? (202)
70) The pipe that connects an approved fuel-fired applieance to a vent is a? (202)
71) A device installed in the venting system for a fuel burning appliance that is designed to automatically open the venting system when in operation and automatically close when not is called a? (202)
72) The natural or mecyhanical process of supplying conditioned or unconditioned air to any space is called? (202)
73) Appliances governed by the mechanical code shall have a factor-applied nameplate affixed that includes which all but which of the following? (301.9)
74) Appliances that comprise parts of the building’s mechanical system shall not be converted for the usage of a diAerent fuel except where approved and? (301.12)
75) Notches on the ends of joists for mechanical piping shall not exceed what percentage of the joist depth? (302.3.1)
76) Notches in non-structural steel wall studs shall have a length no more than? (302.5.3)
77) Appliances shall not be located within hazardous locations unless? (303.2)
78) Non-direct vent fuel fired appliances shall not be located in all of the following except? (303.3)
79) Where conflicts exist between the mechanical code and the manufacturer’s installations, what provisions shall be enforced? (304.2 Exception)
80) Equipment having an ignition source within a repair garage shall be elevated so the ignition source is not less that what distance above the floor surface? (304.3)
81) The maximum output capacity of hydrogen generating appliances shall not exceed four CFM of hydrogen per what square footage of floor space? (304.5.1)
82) The placement of an appliance within a public garage where motor vehicles are capable of passing under the appliance requires at least how much clearance for the bottom of the appliance above the tallest vehicle garage door opening? (304.6)
83) What is the minimum vertical clearance above an unobstructed floor for appliances mounted at the ceiling within a private garage? (304.7)
84) Heat producing equipment and appliances shall be installed to maintain what required clearances to combustibles construction? (304.9)
85) Appliances installed at grade level on a concrete slab shall be not less than how far above adjoining grade? (304.10)
86) Appliances suspended over ground shall provide how much clearance beneath the bottom and the adjoining grade? (304.10)
87) Guards of what height shall be provided appliances require service are mounted within how far from a roof’s edge? (304.11)
88) Where multiple appliances are mounted at a rooftop location, they shall be? (304.12)
89) What is the maximum horizontal spacing for piping supports for 3/4 inch CPVC? (Table 305.4)
90) What is the maximum horizontal spacing for piping supports for 1-1/4 inch CPVC?
91) Non dwelling unit appliance rooms shall have a door and unobstructed passageway not less than what dimensions? (306.2)
92) An appliance alcove within a dwelling unit shall have an opening and unobstructed passageway not less than what dimensions? (306.2 Exception)
93) Appliances within attics shall have anunobstructed passageway not less than what dimensions? (306.3)
94) The passageway serving appliances in an attic shall not be longer than what distance from the opening to the attic? (306.3)
95) Appliances within the attic require which of the following? (306.3.1)
96) Underfloor spaces containing appliances shall be provided with an access opening large enough to remove the largest appliance, but the passageway shall not be smaller than? (306.4)
97) If a mechanical appliance is within a crawl space where the depth of the passageway exceeds 12 inches below the adjoining grade, the walls of the passageway shall be lined where the concrete or masonry lining is at least how far above the adjoining grade? (306.4)
98) Where equipment requiring access is located on an elevated structure or roof of a building, there shall be an exterior means of access if they must climb a ladder more than what height to access the equipment? (306.5)
99) Equipment and appliances on roofs shall not require climbing over obstructions greater than what height above the roof? (306.5)
100) Equipment on sloped roofs that require services shall have a platform of at least 30 inches of working horizontal space on each side of the appliance if the roof slope is more than what? (306.5.1)