1) A luminaire that weighs more than 50 lbs shall be supported independently of the outlet box unless the outlet box is? (314.27(A)(2))
2) Outlet boxes supporting paddle fans shall be? (314.27(C)(1))
3) In straight pulls, the length of the box or conduit body shall not be less than how many times the trade size of the largest raceway? (314.28(A)(1))
4) The distance between raceway entries enclosing the same conductor shall not be less than how many times the trade size of the larger raceway for U-pulls? (314.28(A)(2))
5) Covers of outlet boxes having holes through which flexible cord pendants may pass shall have a? (314.42, 300.4(G))
6) Where run across the top of floor joists or within 7 feet of the floor across the face of rafters, Armored Cable (AC) shall be? (320.23(A))
7) Where Armored Cables (AC) run across the top of floor joists where this space is not accessible by permanently installed stairs/ladders, protection shall only be required within what distance of nearest edge of the scuttle hole or attic entrance? (320.23 (A))
8) Type AC cable shall be secured within 12 inches of every outlet box and supported at intervals not to exceed? (320.30(B))
9) Type AC cable shall be supported at intervals not exceeding? (320.30(C))
10) The rating of Flat Cable (FC) for branch circuits shall not exceed? (322.10(1))
11) Where FC is installed under 8 feet above the floor, it shall be protected by? (322.10(3))
12) Bending radius of Type Metal-Clad Cable shall not be less than 12 times overall diameter of one of the individual conductors or 7 times overall diameter of the multiconductor cable, whichever is? (330.24(C))
13) Type MI cable shall not be used where exposed to conditions that are? (332.12)
14) Type MI cable shall be supported at intervals not exceeding? (332.30)
15) Types NM and NMC Cables shall be concealed within walls provided the walls have at least a? (334.10(3))
16) Types NM and NMC can be in noncombustible construction where installed within? (334.10(5))
17) Type NMC allowed in outside and inside walls of masonry block or? (334.10(B)(2))
18) NM/NMC shall not be used when exposed within a dropped or suspended ceiling cavity in other than? (334.10(2))
19) NM/NMC shall not be embedded in? (334.10(9))
20) Types NM/NMC shall be protected when installed through? (334.17)
21) In accessible attics, Types NM/NMC must be protected if not 7 feet high or under what horizontal distance from attic access hole? (334.23)
22) Bending race shall not be less than how many times the diameter of NM/NMC cable? (334.24)
23) NM/NMC cable shall be supported at intervals not exceeding what distance and within 12 inches over every cable entry into outlet boxes? (334.30)
24) NM/NMC cable is not required to be supported if not more than how far from last point of cable support to a luminaire. (334.30 (B) (2))
25) The ampacity of Types NM/NMC shall not exceed that of a 60° C rated conductor. The 90° C rating shall be permitted to be used for ampacity correction calcs provided that the final calculated ampacity does not exceed that of what temperature rated conductor? (334.80)
26) The Type NM/NMC conductor insulation shall be rated at? (334.112)
27) Type USE is for? (338.2)
28) Type UF allowed for wiring in wet, dry or? (340.10(3))
29) Type UF not allowed in all the following except? (340.12 (1), (2), (8))
30) Each length of IMC shall be clearly and durably marked at least every what distance with the letters IMC? (342.120)
31) RMC is permitted under cinder fill if protected by at least 2 inches of concrete and where fill is at least how deep? (344.10(C))
32) RMC shall be securely fastened within what distance of each box? (344.30(A)(1))
33) Fastening of RMC shall be permitted to be increased to 5 feet where structural members do not permit fastening within? (344.30(A)(2))
34) RMC shall be supported if in exposed vertical risers from industrial machinery at intervals not exceeding? (344.30(B)(3))
35) Running threads shall not be used on RMC conduit for connection at? (344.42(B))
36) FMC less than what size shall not be used (unless by exception)? (348.20(A))
37) FMC shall be securely fastened within 12 inches of each box and shall be supported at intervals not exceeding? (348.30(A))
38) FMC shall be permitted to be used as an Equipment Grounding Conductor if? (348.60)
39) LFMC of what minimum size shall be permitted in certain situations? (350.20 Exception)
40) Rigid PVC conduit is permitted in all the following except? [just look up as I don’t remember the correct one ](352.10(A), (B), (C), 352.12(B))
41) Expansion fittings for PVC conduit shall be provided if the expected thermal expansion is what distance or greater? (352.44)
42) Required support of 1/2 inch to 1 inch PVC is not to exceed? (Table 352.30)
43) 354.10: Nonmetallic Underground Conduit (NUCC) is Permitted in all the following except? (354.10(2), (3), (4), 354.12)
44) 1-1/2-inch NUCC shall have a minimum bending radius of? (354.24, Table 354.24)
45) LFNC shall not be used in lengths longer than? (356.12)
46) The maximum EMT size shall is? (358.20(B))
47) EMT shall not have more than how many 90-degree bends between pull points? (358.26)
48) EMT shall be securely fastened in place at intervals not to exceed 10 feet. Each EMT run shall be fastened within? (358.28(A))
49) Size 3/8 inches FMT shall be permitted in lengths not more than? (360.20(A) Exception No 2)
50) ENT conduit is permitted in any building exceeding 3 floors above grade but requires walls to have a thermal barrier of at least 15 minutes unless? (362.10(2))
51) ENT is not permitted in all but which of the following? (362.12(2), (3), (4), (7))
52) ENT larger than what size shall not be used? (362.20(B))
53) Auxiliary gutters are permitted to extent more than 30 feet beyond supporting equipment if supporting? (366.12(2), Exception)
54) The sum of cross-sectional area of all contained conductors in sheet metal auxiliary gutters shall not exceed what percent of the interior cross-sectional area? (366.22(A))
55) Adjustment factors are applicable where the number of current carrying conductors exceeds how many at any cross section of a sheet metal auxiliary gutter? (366.23 (A), 310.15(C)(1))
56) Expansion fittings shall be installed where expected length change due to thermal change is expected to be more than? (366.44)
57) Auxiliary Gutters that are held together with screws/rivets shall have such fasteners, so they are not spaced more than how far apart? (366.100(B))
58) Busways shall be permitted to extend vertically through dry floors where passing through a minimum distance of how high above the floor to provide adequate protection from damage? (368.10((C)(2))
59) Where a vertical busway riser penetrates two or more dry floors, a minimum curb of what height shall be installed around all floor openings to prevent liquids from entering the opening? (368.10(C)(2)(b))
60) A busway shall be protected against overcurrent in accordance with the rating of the busway but shall be permitted to be increased not to exceed how many amps? (368.17(A) Exception No. 1, 240.4(B))
61) Overcurrent protection shall be permitted where busways are reduced in ampacity provided that the length of the busway does not exceed 50 feet and has an ampacity equal to what portion of the rating of the overcurrent device next back on the line? (368.17(B) Exception)
62) The length of a flexible cord from busway plug-in device to a suitable tension take up support shall not exceed? (368.56(B)(2))
63) The current-carrying conductors in a cable bus shall be sized in accordance with the design of the cable bus but in no case smaller than what size? (370.20(A)(2))
64) Cable bus shall be securely supported at intervals not exceeding what spacing? (370.30(A))
65) The size of conductors in cellular concrete raceways shall not be larger than what size without special permission? (372.20)
66) The maximum number of conductors in a cellular concrete raceway shall not have a combined cross-sectional area of all conductors over what percentage of the cross-section area of the cell or header? (372.22)
67) The largest conductor size without special permission in a cellular metal floor raceway is? (374.20)
68) When insulated conductors of 4 AWG or larger are pulled through a metal wireway (used as a pull box), the minimum required size shall be what multiple of the conduit for straight pulls? (376.22(B) See references in section)
69) Splices and taps shall not fill a metal raceway more than what percentage of the available area? (376.56(A))
70) Nonmetallic wireways shall be supported where run horizontally at intervals not exceeding what distance? (378.30(A))
71) Splices and taps shall be permitted within a nonmetallic wireway provided they are accessible where they do not fill the available area to more than? (378.56)
72) Nonmetallic extensions shall be permitted to run in any direction from an existing outlet to not within how far from the floor? (382.15(A))
73) Strut-type channel raceway shall have all the following permitted except? (384.10, 12)
74) Installation of underfloor raceways that are a less than 1 inches apart are required to be covered in concrete to a depth at least? (390.15(B))
75) Single-conductor cable trays shall be 1/0 AWG or larger and shall be? (392.10(B)(1)(a))
76) For raceways or cables running parallel to and attached to the side of a cable tray, fastening and supporting shall be in accordance with the requirements of the appropriate raceway article? (392.18(G) and 358.30(A))
77) Cable operating at over 1,000 volts in cable trays shall be what type? (392.20(B))
78) Allowable cable fill area? (Table 392.22(A)(6), 392.22(B))
79) Steel cable trays shall not be used as equipment grounding conductors for GF protection circuits above what amperage? (Table 392.60(B) Note, 392.60(B)(2))
80) Open conductors shall be separated by what minimum distance from metal raceways? (398.19)
81) Flexible cords and cables shall conform to the description in Table? (400.4 and know Table 400.4)
82) How may amps is a two-conductor SOW 14 gauge flexible cord rated for? (Table 400.5(A)(1))
83) Splices in flexible cords are permitted provided the cord is what minimum size? (400.13)
84) The insulation of the grounded conductor in a flexible cord can be what color? (400.22)
85) The grounded conductor in a flexible cord ban be distinguished with? (400.22(F))
86) Portable cables over 600 V shall be what minimum size? (400.31(A))
87) The ampacity of 14 AWG fixture wire shall be? (Table 402.5)
88) The maximum overcurrent protection for a 16 AWG flexible cord shall be? (402.14, 240.5(B)(2))
89) Three-way switches shall be wired so that all switching is done only in the? (404.2(A))
90) In damp or wet locations, a flush mounted switch shall be equipped with a? (404.4(B))
91) The operating handle of a switch shall not be higher than? (404.8(A))
92) Switch gear that requires more than 50 lbs to activate shall have a maximum height of? (404.8(A), 490.41(A))
93) Ganged snap switches shall have a voltage that does not exceed? (404.8(B))
94) Snap switches shall be connected to an equipment grounding conductor under what circumstances? (404.9(B))
95) The maximum voltage of a tungsten-filament lamp load activated with a snap switch shall not exceed? (404.14(A)(2))
96) Unless listed otherwise, general-use dimmer switches shall but used to control permanently installed luminaires of what type? (404.14(E))
97) Receptacles designed for the reduction of electrical noise shall be identified by? (406.3(D))
98) Except when an equipment grounding conductor does not exist, 20 A receptacles shall be of the? (406.4(A), 406.4(D)(2))
99) If replacing a non-grounding type receptacle in a home with a GFCI receptacle, the cover plate shall be marked? (406.4(D)(2)(b), (c))
100) When replacing a receptacle that is required to be GFCI, but is not, the replacement GFCI shall be? (406.4(D)(3) including exception)